Conditioning System

ATEEE-ZL Engine Turbo-Charged Air Conditioning System

  • ATEEE-ZL Engine Turbo-Charged Air Conditioning System
  • ATEEE-ZL Engine Turbo-Charged Air Conditioning System
Summary Specification

 Basic Configuration

 

●      Temperature Control Data

Temperature control range: 35~90℃

Temperature control precision: ±0.5℃

Max. intake air temperature of intake intercooler≤250℃

Pressure drop of the largest flow quantity≤5kPa

●      Cooling Unit

Air cooler of the gas-water exchanger

The temperature of chiller water should be less than 25℃, when the controlling temperature is less than 35℃

●      Controlling Unit

Using high precision temperature control regulating valve, the flow ratio as much as 1:1000.

Controlling instruments having functions of temperature controlling, alarm, storage, temperature setting, and communication with upper machine.

Analog and communication quantity input/output: RS485, 4~ 20mA or 0~10V

An integrating installation of the electrical control cabinet


Selecting Unit


●      Heating Unit

Using electrical heating unit

●      Secondary System

Using secondary system to control the temperature, with water pump and water tank and heating function

●      Resistance Adjustment

Manual or automatic air flow saving valve existing in the following of the air pipe after inter cooling, being able to adjust the pressure drop value before and after the inter cooling

●      Other Options

Using automatic water elimination equipment by using charged air



■  Basic Data

 


Type

Parameter

ATEEE-ZL Engine Turbo-Charged Air Conditioning System

ZL1000

ZL3000

ZL6000

Air Flowkg/h

0-1000

0-3000

0-6000

Control Precision

±0.5

±0.5

±0.5

Max. Cooling PowerkW

75

150

300

Max. Range of Temperature Control

35~90

Heating PowerkWAutomatic heating function is not included in the standard product

9

18

36

Max. Power ConsumptionkW

0.5without heating function

10(380V)

with heating function

0.5without heating function

20(380V)

with heating function

0.5without heating function

40(380V)

with heating function

Connection Pipe SizeDN

DN25

Inlet and outlet of lub oil

DN25Inlet and outlet of cooling water

DN25

Inlet and outlet of lub oil

DN25Inlet and outlet of cooling water

DN40

Inlet and outlet of lub oil

DN40Inlet and outlet of cooling water

Weightkg

~80

~120

~300

Applicable Engine PowerkW

Low or medium power engine, less than 250kW

Low or medium power engine, less than 500kW

Low or medium power engine, less than 1000kW

Max. Cooling Water Flow(m3/h)

7.5

15

30

Pressure Loss of max. Air FlowkPa

5

Resistance Regulation

(with resistance regulation in order to adapt to compressed air resistance)

Using manual or electrical butterfly valve, adjustable as you like

Analog Quantity Input/output

4~20mA or 0~10V

Digital Interface

e.g. RS232C/RS485


With cooling water filter

 mesh aperture 50μm